Fire testing performed in accordance with DO-160G, AC20-135, and ISO 9001 standards.
Fixture Capabilities
- Fits 24"x24"x1/4" test panels
- 4Gs of acceleration
- +6 PSI positive pressure differential
- 0 to 1200 feet per minute back side airflow with positive pressure differential
- 0 to -5.5 PSI negative pressure differential
- 0 to 100 feet per minute back side airflow with negative pressure differential
- Alternate non pressure fixture available, along with custom fixture design if necessary
Burner Capabilities
- Jet-A fuel
- 2000鈩
- 4500 BTU/hr
- Methane Bunsen Burner for Interior Burn testing
Testing Capabilities
- FAA Interior Burn per FAR 23.851/25.853
- Firewall/Cowl/Pylon Burn Testing per FAR 23/25 standards
- Developmental Testing (fire proof and fire resistant)
- Certification Testing (fire proof and fire resistant)